Deprecated: Return type of Requests_Cookie_Jar::offsetExists($key) should either be compatible with ArrayAccess::offsetExists(mixed $offset): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/galli2europe.com/public_html/wp-includes/Requests/Cookie/Jar.php on line 63
Deprecated: Return type of Requests_Cookie_Jar::offsetGet($key) should either be compatible with ArrayAccess::offsetGet(mixed $offset): mixed, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/galli2europe.com/public_html/wp-includes/Requests/Cookie/Jar.php on line 73
Deprecated: Return type of Requests_Cookie_Jar::offsetSet($key, $value) should either be compatible with ArrayAccess::offsetSet(mixed $offset, mixed $value): void, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/galli2europe.com/public_html/wp-includes/Requests/Cookie/Jar.php on line 89
Deprecated: Return type of Requests_Cookie_Jar::offsetUnset($key) should either be compatible with ArrayAccess::offsetUnset(mixed $offset): void, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/galli2europe.com/public_html/wp-includes/Requests/Cookie/Jar.php on line 102
Deprecated: Return type of Requests_Cookie_Jar::getIterator() should either be compatible with IteratorAggregate::getIterator(): Traversable, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/galli2europe.com/public_html/wp-includes/Requests/Cookie/Jar.php on line 111
Deprecated: Return type of Requests_Utility_CaseInsensitiveDictionary::offsetExists($key) should either be compatible with ArrayAccess::offsetExists(mixed $offset): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/galli2europe.com/public_html/wp-includes/Requests/Utility/CaseInsensitiveDictionary.php on line 40
Deprecated: Return type of Requests_Utility_CaseInsensitiveDictionary::offsetGet($key) should either be compatible with ArrayAccess::offsetGet(mixed $offset): mixed, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/galli2europe.com/public_html/wp-includes/Requests/Utility/CaseInsensitiveDictionary.php on line 51
Deprecated: Return type of Requests_Utility_CaseInsensitiveDictionary::offsetSet($key, $value) should either be compatible with ArrayAccess::offsetSet(mixed $offset, mixed $value): void, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/galli2europe.com/public_html/wp-includes/Requests/Utility/CaseInsensitiveDictionary.php on line 68
Deprecated: Return type of Requests_Utility_CaseInsensitiveDictionary::offsetUnset($key) should either be compatible with ArrayAccess::offsetUnset(mixed $offset): void, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/galli2europe.com/public_html/wp-includes/Requests/Utility/CaseInsensitiveDictionary.php on line 82
Deprecated: Return type of Requests_Utility_CaseInsensitiveDictionary::getIterator() should either be compatible with IteratorAggregate::getIterator(): Traversable, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/galli2europe.com/public_html/wp-includes/Requests/Utility/CaseInsensitiveDictionary.php on line 91 Biolog Incubatore Refrigerato da Laboratorio – Galli Soluzioni per il Laboratorio e Industria
Incubatore refrigerato Modello Biolog, originale Galli, un frigotermostato da laboratorio ideale per applicazioni di microbiologia, batteriologia, crescita microrganismi, drosophila, daphnia, insetti, alghe, zebra-fish, analisi acque, BOD, termostatazione, fermentazione, cristallografia, test diagnostici, analisi delle acque, fermentazione, test diagnostici e alimentari, la ricerca medica, il controllo qualità, HCCP, la cosmesi, l’industria chimica, farmaceutica e le biotecnologie, crescita della piante.
Quando si deve lavorare intorno o sotto la temperatura ambiente il Termostato Refrigerato modello Biolog offre la la giusta soluzione, nella camera dell’ Incubatore Refrigerato è possibile inserire vetreria da laboratorio come Piastre Petri, Tubi, Provette, Fiasche, Slides a contatto,… il tutto in un luogo ideale di incubazione con la temperatura indispensabile per favorire la crescita dei micro organismi nel loro terreno di coltura, agar semplice o complesso.
La versione Biolog LUX offre un Incubatore Refrigerato con Illuminazione interna comandata da un timer che permette la gestione del cliclo circadiano con la giusta alternanza tra ore di luce e ore di buio.
Agitatori, analizzatori, possono essere inseriti ed alimentati grazie all’accessorio option della presa elettrica interna.
PLUS
• AG-Sysyem: controllo a microprocessore PID Digitale, accurato e sensibile. Versioni: SMART, LUX • Risoluzione +- 0,1°C • Affidabile, sicuro, preciso • Campo di temperatura da +3,0°C a +50,0°C • Versione con illuminazione interna da +15,0°C a +40,0°C (con luci accese) • Versatile e compatto, con porta coibentata e guarnizioni magnetiche • Ideale per lavorare intorno ed al di sotto della temperatura ambiente • Sistema di circolazione aria “AntiDryGalli“, uniforma la temperatura nella camera, limitando l’essiccazione dei terreni di coltura. • Scelta tra 3 volumi, 1 piccolo da banco e 2 da pavimento: 101, 140, 240 Litri • Made in Italy
Caratteristiche
• Camera interna in materiale plastico atossico di colore bianco • Resistenze a basso carico superficiale • Sistema automatico di raffreddamento con compressore ermetico e gas ecologici, rispettosi dell’Ozono • Leggera ventilazione interna per rapido raffreddamento, riscaldamento e ripristino della temperatura
Dotazioni di serie
• N°01/02 Ripiani estraibili • N°01 Cavo di alimentazione • N°01 Manuale di istruzioni • N°01 Certificato di conformità CE • N°01 Certificato di Garanzia